SKU: HWCWQSJGWJB5T99DM001V9
+12
More
VEVOR Infrared Thermometer, -30℃ to 1600℃ Dual-Mode IR Thermometer Gun with K-Type Thermocouple, Dual Laser Heat Temperature Gun Non-Contact for Metal Smelting/Engine/Industry/Cooking (Not for Human)
3 2 Reviews
48 90 €
Each when you buy 0+.
Shop
Get -% off for new user
Get 5,00€ Off 99,00€+ Orders on Your First 3 App Orders.
Download Now
- Dual-Mode Measurement: This infrared thermometer supports non-contact surface temperature measurement from -22 to 2912°F (-30 to 1600°C) and includes a K-type thermocouple probe for contact measurement of internal temperatures from 32 to 392°F (0 to 200°C)
- Wide & High Temperature Range: Featuring a broad -22°F to 2912°F measurement range, this dual-mode infrared thermometer enables precise, fast, and non-contact temperature measurements for multiple household and industrial applications
- Precise Measurement: Designed with dual-laser targeting, high-sensitivity sensor, 0.10-1.0 adjustable emissivity, a 0.5s fast response time, and a 50:1 distance to spot size, this dual laser IR thermometer allows more secure and accurate long-distance measurement
- More User-Friendly Designs: Our digital IR laser thermometer comes with a clear color display, 2pcs 1.5V batteries, high/low temp alarms, ℉/℃ switching, 30s auto shutdown, and a lightweight body, making temperature checks faster and more convenient
- Multi-Purpose Thermometer: Whether for metal smelting, industrial processing, automotive repair, machinery maintenance, electrical inspection, kitchen cooking, grilling, or other household tasks, this dual laser temperature gun has you covered. (Not for human use)
Frequently Bought Together
Reviews
About this item
Questions and Answers
Explore
Reviews
3.0 Out of 5
How customer reviews and ratings work?
Details
How customer reviews and ratings work?
Customer Reviews, including Product Star Ratings help customers to learn more about the product and decide whether it is the right product for them.
Our overall rating is not a simple average. We prioritize authentic, trustworthy reviews and filter out duplicates or invalid content before calculating the final score. This helps ensure the rating truly reflects real customer experiences.
Review this product
Share your thoughts with other customers
Top Reviews
Great instrument
1600°C
This seems to be a quality build product. Easy to use but read the manual to get the most from the settings available to you. The twin laser dots makes it very easy to target you area you are trying to measure. Fairly fast response to arrive at the temperature it senses. Display nice and bright but in strong sunlight a little hard to see but it holds temperature readings to give you time to shade with your hand to read the value. Very comfortable in my hand and the weight is almost negligible. The holster provided has loop for your belt for convenient carrying. The high temp range is perfect for my application to measure my blacksmith’s forge. The probe while limited in the temp range compared to the gun but still useful for around the barbecue. All in all I’m very pleased with the quality and price point for this instrument. I hope it’s lasts me a long time.
1 people found this helpful
Lasers Misaligned when Received
1200°C
Unit did not work upon arrival. I thought maybe I didn't understand how to use it, so I used the VEVOR chat. I explained my issue and I was told someone would get back to me in 1-2 days.
Here's my issue. When I point the gun the two dots are too far apart:
* At 6 inches: The dots are 1.5 inches apart.
* At 6 feet (72 inches): The dots widen to 4 inches apart.
I didn't want to wait two days so I did an AI query and Gemini confirmed the unit was not right.
Your unit is physically misaligned or defective.
Given your measurements, your lasers are actually diverging (spreading outward) instead of converging or staying tightly parallel to the infrared sensor's path:
For a 50:1 Distance-Vevor GT1200, the actual infrared cone of measurement is supposed to be incredibly narrow:
* At 6 inches away, the real area being measured is supposed to be a tiny circle only 0.12 inches wide.
* At 6 feet away, the real area being measured is supposed to be only 1.44 inches wide.
Because your lasers are spanning 4 inches wide at 6 feet, the red dots are pointing far outside of the actual zone the thermometer is reading. The internal laser diodes were likely knocked out of their precise alignment brackets during shipping or manufacturing.
1 people found this helpful
About this item
Description
Pro-level performance without the pro-level cost


This dual-mode infrared thermometer combines non-contact IR temperature measurement from -22 to 2912°F (-30 to 1600°C) with K-type probe contact measurement from 32 to 392°F (0 to 200°C), suitable for a wide range of household and industrial temperature measurement tasks.


50:1 distance to spot size enables extended long-range measurement. Let you securely measure high temperatures without getting too close to the heat source.


Also equipped with a K-type thermocouple probe, this dual laser IR thermometer supports internal contact measurement, enabling more complete temperature measurement and analysis.


Making high-temperature measurement more secure, accurate and efficient. This infrared thermometer temperature gun is ideal for a wide range of household and industrial applications.


Integrating precise measurement, clear display, and an intuitive interface into one device, this IR thermometer enables faster, easier temperature measurement and quick identification of abnormal temperature conditions.


Product guides and documents